LGD F200P2-H NH3

Axetris’ laser gas detection modules are stand-alone, ready-to-use OEM subsystems for selective detection and monitoring of gases. The sensor is based on a technology called “TDLS” – or Tunable Diode Laser Spectrometry, which has proven its validity in high-end laboratory and process control applications. It uses a laser to scan the specific absorption lines of a target gas with an extremely high resolution, which enables a precise measurement of the gas concentration with a very high selectivity. Axetris’ proprietary approach to TDLS leverages this technology to low-cost, high-volume gas detection & monitoring applications: The use of low-cost telecom-type laser diodes as light source, combined with Axetris’ intellectual property of reference channel-free devices, reduces the gas sensor to a set of generic components and enables significant cost synergies across applications.

The LGD gas sensor technology brings a competitive solution to most of the drawbacks of current sensors:

  • Extremely high selectivity to the target gas
  • Functional safety, continuous status reporting
  • Long lifetime (10+ years)
  • Fast response times
  • Low power consumption possible
  • Very low cost-of-ownership (no regular replacement and/or calibration)
  • Low cost of the gas sensor through excellent scaling costs of the com-ponents

Axetris LGD F200P2 – “More Possibilities”
With the introduction of Platform 2, Axetris customers profit from higher gas detection performance due to improvements in product architecture. The new design reduces warmup time of the gas measurement cell, which enables a shorter time to a stable measurement for hot gas applications. Platform 2 further improves on long-term stability by making the product more robust, even in environments with heavy dust concentrations. These improvements translate into lower maintenance effort, and longer zero/span intervals for gas analyzers. Lastly, product modularity makes field service tasks easier and more cost-efficient for the end user.

 



Technical Data

Details LGD F200P2-H NH3 CEM QAL1 + Add to Watchlist + Add to Comparison Print Specifications

Article No. *603.165*

Attribute Unit Value
Measurement Type
Maximum Measuring Range (H2O) % vol. 0 - 40
Maximum Measuring Range ppm 0 - 50
Minimum Measuring Range (H2O) % vol. 0 - 30
Minimum Measuring Range ppm 0 - 15
Measuring Range Details
Precision 2σ ppm 0.2
Precision 2σ (H2O) ppm 1000
Target Gas NH3 (H2O)
Accuracy % +/-2
Accuracy Details
Precision Details
Details LGD F200P2-H NH3 SCR 220C + Add to Watchlist + Add to Comparison Print Specifications
Details LGD F200P2-H NH3 SCR Ind + Add to Watchlist + Add to Comparison Print Specifications

Scope of delivery

LGD F200 OEM-module, manual, accessories