We use Cookies to give you a better experience while surfing on our website and we use such data for statistical purposes. By applying the adequate settings in your browser you have control over the acceptance of Cookies. Find out more here

Axetris Europe

Axetris Amerikas

Asia+Oceania

Africa+Middle East

  • Switzerland | DE / EN
  • Germany | DE / EN
  • Turkey | EN
  • Rest of the World | EN
  • Great Britain | EN
  • Canada | EN
  • USA | EN / DE / ZH / JA
  • Rest of the World | EN
  • 中国 | ZH / EN / JA
  • India | EN
  • 日本 | JA / EN
  • 대한민국 | EN
  • Rest of the World | EN
  • Rest of the World | EN

LGD Compact-A NH3 – Launch 2021

Axetris’ Laser Gas Detection modules LGD Compact-A NH3/H2O  can be a benefit for many environmental applications like monitoring of NH3 emissions in agriculture and livestock and also for quality control  in biogas production. 
Furthermore, the detection of NH3 in human breath can help to detect diseases at an early stage and thereby contributes to cost savings in healthcare systems.
Product available by Q1 2022

Benefits at a Glance:
- Designed for portable instruments
- Sub ppm detection limits
- high target gas selectivity

Technical Data

Details LGD Compact-A NH3/H2O + Add to Watchlist + Add to Comparison Print Specifications

Article No. *605.226*

Attribute Unit Value
Target Gas NH3
Second Target Gas H2O
Measurement Type (EN) extractive, ambient / (DE) extraktiv, ambient
Measurement Range NH3 ppm 0-100
Measuring Range H2O % vol. 0-5
Measuring Range Details Calibration to full scale (FS) range, standard is 100 ppm, (possible up to 40'000 ppm, no warranty of precision)
Accuracy NH3 ppm +/-1
Accuracy H2O % +/- 0.2
Accuracy Details The accuracy is defined as the difference between the mean response during a 2 min time interval and the reference value at reference conditions. Variations of the operating temperature and pressure can affect the accuracy of the system.
Precision 2sigma NH3 ppm 0.8
Precision 2 sigma H2O % vol 0.15
Precision Details (EN) The precision is defined as 2 times the standard deviation s of a 2 min measurement at stable reference conditions over the full measuring range. The precision of the system can be improved by mean of averaging. / (DE) Die Präzision ist definiert als das Zweifache der Standardabweichung s einer 2-minütigen Messung unter stabilen Referenzbedingungen über den gesamten Messbereich. Die Präzision des Systems kann durch Mittelwertbildung verbessert werden.
Sampling Rate Hz 0.5