LGD F200P2-H NH3

Axetris’ laser gas detection modules are stand-alone, ready-to-use OEM subsystems for selective detection and monitoring of gases. The sensor is based on a technology called “TDLS” – or Tunable Diode Laser Spectrometry, which has proven its validity in high-end laboratory and process control applications. It uses a laser to scan the specific absorption lines of a target gas with an extremely high resolution, which enables a precise measurement of the gas concentration with a very high selectivity. Axetris’ proprietary approach to TDLS leverages this technology to low-cost, high-volume gas detection & monitoring applications: The use of low-cost telecom-type laser diodes as light source, combined with Axetris’ intellectual property of reference channel-free devices, reduces the gas sensor to a set of generic components and enables significant cost synergies across applications.

The LGD gas sensor technology brings a competitive solution to most of the drawbacks of current sensors:

  • Extremely high selectivity to the target gas
  • Functional safety, continuous status reporting
  • Long lifetime (10+ years)
  • Fast response times
  • Low power consumption possible
  • Very low cost-of-ownership (no regular replacement and/or calibration)
  • Low cost of the gas sensor through excellent scaling costs of the com-ponents

Axetris LGD F200P2 – “More Possibilities”
With the introduction of Platform 2, Axetris customers profit from higher gas detection performance due to improvements in product architecture. The new design reduces warmup time of the gas measurement cell, which enables a shorter time to a stable measurement for hot gas applications. Platform 2 further improves on long-term stability by making the product more robust, even in environments with heavy dust concentrations. These improvements translate into lower maintenance effort, and longer zero/span intervals for gas analyzers. Lastly, product modularity makes field service tasks easier and more cost-efficient for the end user.

 



Technical Data

Details CEM QAL1 + Add to Watchlist + Add to Comparison Print Specifications

Article No. *603.165*

Attribute Unit Value
Measurement Type extractive, hot 190°C
Target Gas NH3 & H2O
Maximum Measuring Range (NH3) ppm 0 - 50
Minimum Measuring Range (NH3) ppm 0 - 15
Maximum Measuring Range (H2O) % vol. 0 - 40
Minimum Measuring Range (H2O) % vol. 0 - 30
Measuring Range Details Calibration to full scale (FS) range, standard is 15 ppm, for safety reasons max. calibration to 100 ppm (linearity up to 500 ppm, no warranty of precision)
Precision 2σ (NH3) ppm 0.2
Precision 2σ (H2O) ppm 1000
Accuracy % +/-2
Accuracy Details Full scale reading depending on integration stability (temperature & pressure)
Precision Details The precision is defined as 2 times the standard deviation sigma of a 5 minute measurement at stable reference conditions. System performance is precision-limited (not accuracy-limited) when the system temperature is stable.
Details SCR Ind. 220C + Add to Watchlist + Add to Comparison Print Specifications
Details SCR Ind. + Add to Watchlist + Add to Comparison Print Specifications

Scope of delivery

LGD F200 OEM-module, manual, accessories