LGD F200P2-H NH3

Axetris’ Laser Gas Detection modules LGD F200P2-H NH3 fitting perfectly to a wide range of industrial applications where reliability and real-time measurement combined with high performance matters. This sensor design has already proven its performance in NH3 slip measurements at power plants and waste incinerators and is also available as a QAL1 compliant version.

 

Benefits at a Glance:

- Long-term stability
- Quicker warm-up time
- Service-friendly design

Technical Data

Details CEM QAL1 + Add to Watchlist + Add to Comparison Print Specifications

Article No. *603.165*

Attribute Unit Value
Target Gas NH3 & H2O
Measurement Type extractive, hot 190°C
Maximum Measuring Range NH3 ppm 0 - 50
Minimum Measuring Range (NH3) ppm 0 - 15
Maximum Measuring Range (H2O) % vol. 0 - 40
Minimum Measuring Range (H2O) % vol. 0 - 30
Measuring Range Details (EN) Calibration to full scale (FS) range, standard is 15 ppm, for safety reasons max. calibration to 100 ppm (linearity up to 500 ppm, no warranty of precision) / (DE) Kalibrierung auf den vollen Skalenbereich (FS), Standard ist 15 ppm, aus Sicherheitsgründen max. Kalibrierung auf 100 ppm (Linearität bis 500 ppm, keine Garantie der Genauigkeit)
Precision 2σ (NH3) ppm 0.2
Precision 2σ (H2O) ppm 1000
Accuracy % +/-2
Accuracy Details (EN) Full scale reading depending on integration stability (temperature & pressure) / (DE) Skalenendwert abhängig von der Integrationsstabilität (Temperatur und Druck)
Precision Details (EN) The precision is defined as 2 times the standard deviation sigma of a 5 minute measurement at stable reference conditions. System performance is precision-limited (not accuracy-limited) when the system temperature is stable. / (DE) Die Präzision ist definiert als das Zweifache der Standardabweichung sigma einer 5-minütigen Messung unter stabilen Referenzbedingungen. Die Systemleistung ist in der Präzision begrenzt (nicht in der Genauigkeit), wenn die Systemtemperatur stabil ist.
Details SCR Ind. 220C + Add to Watchlist + Add to Comparison Print Specifications
Details SCR Ind. + Add to Watchlist + Add to Comparison Print Specifications

Scope of delivery

LGD F200 OEM-module, manual, accessories

Item added to watchlist