LGD Compact-A CH4/C2H6

Axetris’ Laser Gas Detection modules LGD Compact-A CH4/C2H6 are an extension of the CH4 modules for leak detection in order to be able to confirm the source of a CH4 leak in real time.

The user can decide to measure only CH4 or both gases simultaneously, which eliminates the need for further measuring equipment and makes the measurement even more user-friendly.

 

Benefits at a Glance:

- Designed for portable instruments
- Two target gases in real time measurement
- Single- and dual-gas mode available

技术数据

Details CH4 0-100 ppm/0-4 %vol.; C2H6 0-1000 ppm; 0.7 Hz + Add to Watchlist + Add to Comparison Print Specifications

订购号 *604.995*

属性 单位 价值
目标气体 CH4
Second Target Gas C2H6
测量类型 extractive, ambient
Minimum Measuring Range CH4 ppm 0 - 100
Maximum Measuring Range CH4 % vol. 0 - 4
Measuring Range C2H6 ppm 0 - 1000
测量范围细节 Calibration to full scale (FS) range
Accuracy CH4 % FS +/- 3
Accuracy C2H6 % FS +/- 2 or 4 / % CH4, whichever is larger
精度详述 The accuracy is defined as the difference between the mean response during a 2 min time interval and the reference value at reference conditions. Variations of the operating
Precision 2σ Min. Measuring Range CH4 ≤ 1.5
Precision 2σ Max. Measuring Range CH4 ppm ≤ 250
Precision 2σ Measuring Range C2H6 ppm ≤ 20 or 10 / % CH4, whichever is larger
精准度详述 The precision is defined as 2 times the standard deviation s of a 2 min measurement at stable reference conditions over the full measuring range. The precision of the system can be improved by mean of averaging.
Sampling Rate Hz 0.7
Temperature Limitation °C 0 to +40