供热通风与空气调节控制(HVAC)
Infrared Sources for Environmental Applications

Heating, Ventilating and Air Conditioning

Gas sensors based on various sensing technologies are used extensively in heating, ventilating and air conditioning (HVAC) systems. Gas sensors are integrated into control loops to achieve an efficient HVAC system control.

 

Demand-Controlled Ventilation

One of the biggest challenges to design effective HVAC system control is to optimize for actual occupancy. Demand Controlled Ventilation (DCV) has become an increasingly important element to achieve this goal. Often, CO2 gas sensors are used to measure occupancy levels in closed environments (homes, office buildings, car cabins, etc.)

NDIR gas sensors deliver a high performance for HVAC and DCV systems, offering key advantages such as sensor stability, low cost-of-ownership, and being potentially calibration-free.

 

Advantages of Axetris Infrared Sources :

- High emission at 4.26μm

- Small size

- Fast electrical modulation (Modulation frequency: >10Hz)

- High modulation depth

- Low power consumption

- Long lifetime

Axetris offers solutions by providing a portfolio of IR sources with several reflector with /or without integrated windows (BaF2, CaF2, GeART100)


室内空气质量(IAQ)及VOC监测
Infrared Sources for Environmental Applications

Indoor Air Quality and VOC Monitoring

Indoor air pollution has rightly been described as by far the most deadly risk globally. Main contributors to a poor Indoor Air Quality (IAQ) are gases such as CO but also Volatile Organic Compounds.

 

Volatile Organic Compounds, or VOCs, are substances which are volatile at ambient conditions and thus, potentially harmful. VOCs such as benzene, formaldehyde and naphthalene are unfortunately emitted by a number of consumer products and are known to have adverse health effects. Further, VOCs are also known for their tendency to react with ground-level ozone to form secondary pollutants which can adversely affect human health. Intensified study of the effects of VOCs as a major source of indoor and outdoor pollution has motivated environmental agencies worldwide, such as the U.S. EPA and European Union bodies to define guideline concentration values of such VOCs.

 

NDIR technology delivers high measurement performance for typical VOCs, especially since most VOCs are large molecules with a high degree of absorbance for infrared (IR) light.

 

Advantages of Axetris Infrared Sources :

- High emission at 4.26μm

- Small size

- Fast electrical modulation (Modulation frequency: >10Hz)

- High modulation depth

- Low power consumption

- Long lifetime

Axetris offers solutions by providing a portfolio of IR sources with several reflector with /or without integrated windows (BaF2, CaF2, GeART100).


空气质量监测
Infrared Sources for Environmental Applications

Air Quality Monitoring

Most governments and environmental agencies across the world have recognized the dangers of air pollution and implemented guidelines and limits to common pollutants such as CO, Ozone, NOx, SOx, etc. Typically, real-time concentration values are today made available to the public through displays in public places or online.

 

NDIR measurement technology provides an effective way of measuring outdoor air quality by providing solutions which are stable, robust, and maintenance-free.

 

Advantages of Axetris Infrared Sources :

- High emission at 4.26μm

- Small size

- Fast electrical modulation (Modulation frequency: >10Hz)

- High modulation depth

- Low power consumption

- Long lifetime

Axetris offers solutions by providing a portfolio of IR sources with several reflector with /or without integrated windows (BaF2, CaF2, GeART100).


EMIRS 200

Chip on TO header

EMIRS200 on TO39

仅带芯片的光源

Customized

EMIRS200 on TO39 with customized Assembly (special Reflector, Flex-print, etc.)

客户定制

TO39 with Cap

EMIRS200 on TO39 with Metal Cap

带有保护帽 的TO39封装

TO39 with Reflector 1

EMIRS200 on TO39 with Reflector 1 (Focal length 5-15mm) and 4 kinds of Windows

带有反射面1的TO39封装

TO39 with Reflector 2

EMIRS200 on TO39 with Reflector 2 (Focal length 0-7mm)

带有反射面2的TO39封装

TO39 with Reflector 3

EMIRS200 on TO39 with Reflector 3 (Focal length 10-30mm) and 2 kinds of Windows

带有反射面3的TO46封装

TO39 with Reflector 4

EMIRS200 on TO39 with Reflector 4 (Focal length: 0 - 30 mm) and 4 kinds of Windows

带有反射面4的TO46封装

EMIRS 50

Chip on TO header

EMIRS50 on TO46 Basic Version (Chip on Header only)

仅带芯片的光源

Customized

EMIRS50 on TO46 Customized

客户定制

TO46 with Cap

EMIRS50 on TO46 with Cap

带有保护帽的TO46封装

TO46 with Reflector 5

EMIRS50 on TO46 with Reflector 5 and optional Sapphire or BaF2 Window

带有反射面5的TO46封装

TO46 with Reflector 6

EMIRS50 on TO46 with Reflector 6 - no window - back vented

Axetris_IRS_TO46_withreflector6_603_940

TO46 with Reflector 7

EMIRS50 on TO46 with Reflector 7 - no window - back vented

Axetris Infrared Source EMIRS50 with Reflector 7